Section 10. Troubleshooting
Use the troubleshooting information in the following table for suggestions.
Symptom Problem Corrective Action
All lights fail to illuminate Lights are not reciev-
ing power
Check 120VAC power supply
into transformer. Check for
12VAC output at transformer.
Check or reset GFCI. Make
sure 120 volts has not been
used in the installation - if so
damage is assured and is NOT
WARRANTABLE.
One or more lights are
dim, blinking or not
working
Poor connection or
improper wire gauge
Separate each light and
independently wire 12V to the
single light only. Repeat this
process on each light. If junc-
tion box is being used, check
for proper connection of light
cord. Verify that the correct wire
gauge is being used between
the transformer and junction
box.
Colored lights out of
synch
Improper voltage
supply or poor con-
nection to the light
Verify that proper wire connec-
tions are being achieved for
the lights that are out of sync.
Reset all the lights to white by
turning lights OFF for ve (5)
seconds, then turning ON
Light is blinking Light is too hot Conrm that the light is
submerged in water that does
not exceed a temperature of
104F (40C)