UMG 96RM-PN
Serious errors
When a serious error occurs, the device must be sent in
to the manufacturer for inspection.
Error Error description
EEE
910
Error when reading the calibration.
Error Error description
0x01 EEPROM not responding
0x02 Address below range
0x04 Checksum error
0x08 Error in the internal I2C bus
Example error message 911:
This error number is composed of serious error 910 and
the internal error cause 0x01.
In this example an error occurred when reading the calibration
from the EEPROM. The
device must be sent in
to the manufacturer for
inspection.
Internal error causes:
In some cases, the UMG 96RM-PN can determine
the cause for a serious internal error and report it using
the following error codes.