Page 2 = Peak value = Minimum value = Supply
Table of contents
Receipt control 3
Product description 4
Intended use 4
Hints for the user 4
Functional description 4
Hints for Maintenance 5
Repairs and calibration 5
Front foil 5
Waste management 5
Installation 6
Mounting place 6
Measurement and supply voltage 6
Current measurement 6
Sum current measurement 6
Connection diagrams 7
Installation and putting into service 8
Program current and voltage transformers 8
Connect current transformers 8
Check phase assignment 9
Check current flow 9
Removal of errors 10
Service 11
Usage and display 12
Indication mode 12
Measured values 12
Mean values 12
Energying hours meter 12
Programming mode 12
Key functions 13
Table 1, Measured value indications 14
Password 16
Current transformer 16
Programming 16
Voltage transformer 17
Programming 17
Outputs K1 and K2 18
Usage as switching output 19
Programming as switching output 19
Usage as pulse output 20
Programming as pulse output 20
Pulse valency 21
Minimum pulse width 22
Programming of minimumpulse width 22
Averaging times (Bimetal function) 23
Method of taking the mean 23
Programming of averaging times 23
Measured value rotation 24
Programming of rotation time 24
Measured value selection 25
Programming of the measured value
selection 25
Delete minimum and maximum values 26
Delete 26
Delete energy 26
Delete 26
LCD contrast 27
Programming of LCD contrast 27
Software Release 27
User password 27
Indicating range and accuracy 28
Configuration data 29
Technical data 30
Ambient conditions 30
Measurement 30
Outputs 30
Connectable cables 30
Back side 31
Side wiew 31
Brief instructions 32
Programming of current transformer 32
Call up measured values 32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the janitza UMG 96 and is the answer not in the manual?

janitza UMG 96 Specifications

General IconGeneral
Power MeasurementActive, reactive, apparent power
Power Factor MeasurementYes
Frequency Measurement Range45 - 65 Hz
Accuracy Class0.5S (IEC 62053-22)
Energy MeasurementActive, Reactive Energy
Communication InterfacesRS-485, Ethernet
Power Supply85...265 V AC/DC
Protection ClassIP20
Dimensions96 x 96 x 78 mm