EasyManua.ls Logo

Janome 1600P - Feed Cam Timing

Janome 1600P
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
5. Feed Cam Timing
To Check:
[1] Lower the needle bar by turning the handwheel until
the point of the needle is 17.9 mm (for 1600P-DB/
DBX) or 17.5 mm (for 1600P) above the upper
surface of the needle plate (1).
[2] The feed dogs should not move when moving the
reverse stitch lever up and down.
If the feed dogs move, adjust the feed cam timing as
follows.
To Adjust:
[1] Remove the base and lay the machine on its back.
[2] Lower the needle bar until the needle point is 17.9
mm (for 1600P-DB/DBX) or 17.5 mm (for 1600P)
above the needle plate (1).
(Use the third step from the right for 17.9 mm or the
marking for 17.5 mm on the Gauge 767G-001).
[3] Loosen the setscrews (2).
While moving the reverse stitch lever, turn the feed
cam (3) in the direction either A or B until the feed
dogs stop moving.
[4] Tighten the setscrews (2) and attach the base.
(1)
(3)
(2)
A
B
17.9 mm (1600P-DB/DBX)
17.5 mm (1600P)
17.9 mm
17.5 mm