14. Needle Stop Position
[1] Turn the power switch (1) on while pressing the Up/
Down needle position button (2) and bobbin winding
button (3) at the same time.
[2] Remove the top cover.
[3] Lower the needle bar by turning the hand wheel until
the needle point is 19.1 mm (for 1600P-DB/DBX) or
18.7 mm (for DP-1600P) above the upper surface of
the needle plate (4).
(Use the first step from the right for 19.1 mm or the
second step from the right for 18.7 mm).
[4] Loosen the setscrew (5). Rotate the upper shaft
shielding plate (6) toward you until the green LED (7)
turns on.
[5] Tighten the setscrew (5) and turn the power switch
off.
[6] Attach the top cover.