EasyManua.ls Logo

Janome 1600P - Knee Lifter Lever

Janome 1600P
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
13. Knee Lifter Lever
The presser foot rises 7.5 mm when it is fully raised with
the knee lifter.
[1] Remove the base and lay the machine on its back.
[2] Loosen the nut (1) on the knee lifter lever (2) slightly
and turn the adjusting screw (3) to adjust the height.
- If it is lower than 7.5 mm, turn the adjusting screw
(3) clockwise.
- If it is higher than 7.5 mm, turn the adjusting screw
(3) counterclockwise.
(Use the 5th step from the left of the Gauge 767G-001
for 7.5 mm).
[3] Tighten the nut (1) firmly and attach the base.
NOTE:
Lower the needle bar to the lowest position and check if
the needle clamp does not hit against the presser foot
when it is fully raised.
7.5 mm
(1)
(2)
(3)
7.5 mm

Related product manuals