26
6. Auto Tension Release
[1] Turn the handwheel toward you to raise the needle
bar until the needle point is just above the needle
plate.
[2] Lower the presser foot.
Set the tension dial at 4 and push the solenoid disk
(1) fully to the right. The tension disks should open 1
mm.
[3] Loosen the lock nut (2) and turn the adjusting nut (3)
to adjust the gap between the tension disks.
- If the gap is too wide, tun the adjusting nut counter-
clockwise.
- If the gap is too narrow, tun the adjusting nut clock-
wise.
[4] Tighten the lock nut (2).
1 mm
(1)
(2)
(3)