3-2-6 JPH-3004/JPH-5004, Head Type
Fix the Electro Press to the mounting base at the screw holes using 12 M24 hexagon socket bolts
(JIS Strength 12.9, Length 85 mm or more) and washers.
Tighten the bolts to 650 Nm tightening torque.
Fit the switch box to the Electro Press with 4 screws (M4) using the screw holes on the rear of the
unit.
(Mounting Screw Hole)
Ram Center
(Mounting Hole)
Switch Box (Rear)