17
!
1s
1s
4
Standard 4T mode:
Push the torch trigger: arc is ignited and current
reaches the initial value.
Release it: current rises gradually.
Push it again: current drops to pilot arc current
value.
Release it: arc stops.
5
Double operation 4T mode:
Push the torch trigger: arc is ignited and current
reaches the initial value. The torch trigger can be
released at any time.
Release it: current rises gradually. The torch trigger
can be released at any time.
Push it again: current drops to pilot arc current
value. The torch trigger can be released at any time.
Release it: arc stops.
6
Cycle single operation mode without initial current:
" Push the torch trigger: arc is ignited and current
rises gradually.
" Release it: current drops to pilot arc current value.
" Push it again: current rises gradually again, and
then turn to .
" If push the torch trigger and release it at once, arc
will stop.
7
Cycle single operation mode with initial current:
" Push the torch trigger: arc is ignited and current
reaches the initial value.
" Release it: current rises gradually.
" Push it again: current drops to pilot arc current
value, and turn to .
" If release the torch trigger and push it at once, arc
will stop.
8
Inner timing operation mode:
Push the torch trigger: arc is ignited and current
rises gradually.
If release it within 1s, arc will stop; if release it after
1s, it will turn to .
Push it again: current drops gradually, and arc
stops. The torch trigger can be released at any
time.
If push the torch trigger again before arc stops, the
current will gradually rise again, and then turn to .
9
Outer timing operation mode:
" Push the torch trigger: arc is ignited and current
rises gradually.
" If release it within 1s, it will turn to ; if release it
after 1s, arc will stop.
" Push it again: current drops gradually, and arc
stops.