Maintenance
Drum
117 9831/7750-1 117
Figure 67.
A Nozzle B End cap
C Sprinkler/spray pipe D Drain tap
Draining of Water at Pump
1. Make the machine safe.
Refer to: General (Page 87).
2. Get access to the water pump. Refer to Figure 68.
Figure 68.
A Access panel
3. Push the lever to disconnect the hoses from the pump. Refer to Figure 69.