15BOEING 787: FIBER INSPECTION AND CLEANING
CLEAN: JDSU CLEANBLAST SYSTEM
CLEAN
CLEANING WITH CLEANBLAST
To clean receptacles with the CleanBlast system:
1. Install the appropriate cleaning tip to the
CleanBlast handset.
2. PRIME the nozzle if necessary
(see CleanBlast User Manual).
3. Align the alignment guide and insert into
either side of the receptacle or plug (pins or
socket).
4. Insert the handset into the alignment guide
and push to disengage safety mechanism (the
POWER/READY light will turn green), and press
the run button to initiate cleaning.
5. INSPECT the receptacle or plug.
6. Determine whether clean or dirty.
If clean, do not touch it and CONNECT.
If dirty, repeat CLEAN.
Note: Embedded/mated debris cannot be
cleaned, and bonded/burned debris must be
physically cleaned before using CleanBlast.
3
Alignment Guide
(FBPT-A801-2002R)
Cleaning Tip
1
Run Button
4
Focus Control
5
6