Chapter 5 Examples
Executing an action
SmartClass E1 Tester Remote Control Reference Guide 25
b To insert multiple errors
rc s_set E1Bert.0.BertTx.ErrorInsertionType MULTIPLE
rc s_set E1Bert.0.BertTx.ErrorQuantity 3 (quantity 1-50)
rc a_execute E1Bert.0.BertTx.ErrorMultiInsert
c To insert errors at a rate
rc s_set E1Bert.0.BertTx.ErrorInsertionType RATE
rc s_set E1Bert.0.BertTx.ErrorRate 1E3
rc a_execute E1Bert.0.BertTx.ErrorRateInsert (start)
rc a_execute E1Bert.0.BertTx.ErrorRateInsert (stop)
3 To insert other errors, use the following format, but replace the “...” with
one of the items.
rc a_execute …
E1Bert.0.BertTx.SlipInsert (insert a pattern slip error)
E1Bert.0.E1FrameTx.AlarmAisInsert
E1Bert.0.E1FrameTx.AlarmLofInsert
E1Bert.0.E1FrameTx.AlarmMFAisInsert
E1Bert.0.E1FrameTx.AlarmMFRaisInsert
E1Bert.0.E1FrameTx.AlarmRaisInsert
E1Bert.0.E1FrameTx.CrcErrorInsert
E1Bert.0.E1FrameTx.EbitErrorInsert
E1Bert.0.E1FrameTx.FasErrorInsert
E1Bert.0.E1FrameTx.MFasErrorInsert
E1Bert.0.E1Output.AlarmLosInsert
E1Bert.0.E1Output.ErrorInsert
4 To reset the test, use the following format, but replace the “...” with one of
the items.
rc a_execute …
E1Bert.TimedTest.Reset
E1Bert.TimedTest.ResetHistoryResults