22
SPX532 – QUICKSTART GUIDE
10.8. SELF-LEVELING BUTTON
Thanks to the biaxial planimetric sensor, the SPX532 can be
stabilized automatically by holding the Self-leveling button.
NOTE:
The self-leveling function will operate only outriggers down
maneuvers (LIFTING UP THE MACHINE).
The self-leveling function stops when you release the button or
when carrier’s inclination is 0° on both axes.
The self-leveling doesn’t prevent the outriggers / turret
interference (see chapter 9.8)!
10.9. SELF-LEVELING CONDITIONS
Self-leveling function can be operated if:
• outriggers functions are enabled
(see chapters 10.1 and 10.2);
• all 4 outriggers have the same swing angle
(not possible at 0° or 90°).
The self-leveling function is possible even if some
outriggers are extended and some outriggers are
retracted.
Self-leveling not allowed with all
outriggers at 0° or all outriggers at 90°