Wired Controller DWCR2
15
3.7.6 Save Function Setting
Enter user function page. Press or button to select save function and
press
or
button to turn on or turn off save function. Press MENU button to
enter save function setting page.
Enter the save function setting page, and press “
” or
” button to select
cooling or heating limitation temperature. After selecting cooling or heating limitation
temperature, press or button to adjust limitation temperature value. After
setting, press MENU button to save the setting.
Note:
When save function is set, auto mode cannot be set.
3.7.7 This section left intentionally blank
3.7.8 X-fan Function Setting
Enter user function page, press or “button to select dry function option, and
press “
” or
” button
to turn on or turn off this function with auto saving.
Note:
This function is only available in cooling mode and dry mode;
When this function is on, if the air conditioner is turned off, the indoor fan will
still operate at low speed for a while to dry the residual water inside the
unit.