Table 30: 2.5 ton heating charging chart for XA(F,H)*36D and JH(E,V)T*(30,36)D in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
750
Liquid
pressure
(subcool)
329
(16)
372
(15)
415
(14)
306
(14)
341
(14)
392
(15)
295
(15)
333
(17)
371
(20)
270
(20)
315
(19)
359
(17)
258
(19)
292
(22)
338
(24)
249
(23)
288
(24)
328
(26)
235
(24)
273
(26)
312
(27)
1000
Liquid
pressure
(subcool)
290
(15)
331
(14)
372
(14)
273
(12)
310
(13)
352
(12)
265
(14)
301
(16)
338
(18)
247
(17)
286
(17)
326
(17)
236
(15)
273
(19)
311
(17)
227
(16)
265
(17)
303
(18)
216
(17)
253
(18)
289
(19)
1250
Liquid
pressure
(subcool)
264
(16)
304
(16)
344
(15)
251
(15)
291
(13)
327
(13)
244
(13)
282
(16)
318
(17)
232
(16)
270
(17)
307
(19)
225
(17)
262
(18)
298
(19)
216
(20)
253
(21)
291
(21)
207
(19)
243
(20)
280
(21)
-
Suction
pressure
110 114 118 98 99 101 88 85 83 69 71 72 56 57 58 49 49 50 41 41 42
Table 31: 2.5 ton heating charging chart for XA(F,H)*36D and JH(E,V)T*(30,36)D in downflow and horizontal right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
750
Liquid
pressure
(subcool)
333
(15)
376
(14)
419
(13)
310
(13)
344
(13)
396
(14)
298
(14)
337
(16)
375
(18)
273
(18)
318
(17)
363
(16)
261
(21)
296
(23)
342
(26)
252
(25)
292
(26)
332
(28)
238
(26)
277
(28)
316
(29)
1000
Liquid
pressure
(subcool)
296
(13)
337
(12)
378
(12)
277
(11)
315
(12)
358
(11)
269
(12)
307
(14)
344
(17)
251
(15)
292
(15)
332
(15)
240
(17)
279
(22)
317
(20)
231
(19)
270
(20)
309
(21)
220
(20)
258
(21)
294
(22)
1250
Liquid
pressure
(subcool)
270
(14)
310
(14)
352
(13)
257
(13)
298
(12)
334
(12)
250
(12)
288
(14)
325
(15)
237
(14)
276
(15)
314
(18)
229
(18)
267
(19)
303
(19)
220
(21)
258
(22)
296
(22)
211
(19)
247
(21)
285
(22)
-
Suction
pressure
112 116 120 100 101 103 89 86 84 70 72 73 56 57 58 49 49 50 41 41 42
Table 32: 3 ton heating charging chart for XA(F,H)*36D and JH(E,V)T*36D in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
950
Liquid
pressure
(subcool)
350
(30)
397
(32)
442
(34)
324
(35)
370
(37)
414
(39)
308
(38)
354
(41)
401
(43)
291
(38)
337
(41)
382
(45)
276
(40)
316
(44)
356
(47)
264
(42)
305
(45)
347
(48)
241
(39)
281
(42)
321
(44)
1200
Liquid
pressure
(subcool)
325
(30)
361
(34)
417
(36)
305
(36)
340
(34)
394
(40)
293
(38)
328
(42)
383
(45)
277
(39)
311
(43)
365
(46)
262
(42)
296
(42)
345
(49)
251
(45)
286
(48)
334
(52)
233
(41)
267
(45)
313
(48)
1450
Liquid
pressure
(subcool)
293
(26)
338
(28)
382
(30)
279
(30)
322
(32)
365
(34)
270
(31)
314
(34)
358
(37)
255
(33)
297
(36)
339
(40)
243
(36)
284
(40)
326
(43)
234
(38)
273
(41)
313
(45)
220
(35)
259
(38)
298
(41)
-
Suction
pressure
123 124 124 98 99 100 84 85 86 71 70 70 54 54 54 45 46 47 36 37 38
R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series 23
Johnson Controls Ducted Systems