Heating charging charts
Table 24: 1.5 ton heating charging chart for XA(F,H)*24B and JH(E,V)T*18B in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
450
Liquid
pressure
(subcool)
337
(20)
378
(20)
419
(20)
309
(22)
352
(24)
395
(26)
294
(24)
336
(25)
379
(27)
275
(29)
316
(29)
358
(28)
269
(29)
306
(30)
344
(31)
255
(31)
294
(31)
333
(32)
255
(29)
273
(29)
290
(30)
585
Liquid
pressure
(subcool)
316
(19)
357
(19)
398
(20)
288
(19)
327
(19)
378
(25)
281
(23)
323
(25)
365
(27)
263
(27)
305
(27)
347
(27)
251
(25)
280
(23)
325
(28)
239
(27)
277
(28)
315
(29)
241
(30)
260
(29)
280
(28)
750
Liquid
pressure
(subcool)
294
(19)
335
(19)
376
(19)
267
(17)
314
(21)
360
(25)
267
(23)
309
(24)
351
(26)
252
(25)
294
(26)
337
(26)
233
(21)
269
(22)
305
(24)
224
(23)
260
(24)
297
(26)
227
(31)
248
(28)
269
(26)
-
Suction
pressure
132 133 134 107 107 108 95 96 97 79 80 82 61 60 63 52 53 54 42 42 43
Table 25: 1.5 ton heating charging chart for XA(F,H)*24B and JH(E,V)T*18B in downflow and horizontal right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
450
Liquid
pressure
(subcool)
353
(19)
395
(19)
438
(19)
322
(20)
368
(22)
413
(24)
307
(22)
352
(24)
395
(26)
287
(28)
330
(27)
373
(27)
272
(27)
309
(28)
347
(29)
257
(29)
297
(29)
336
(30)
257
(27)
276
(27)
293
(28)
600
Liquid
pressure
(subcool)
324
(17)
366
(18)
408
(18)
295
(18)
333
(20)
387
(23)
288
(21)
331
(22)
374
(24)
270
(24)
313
(24)
356
(24)
251
(25)
288
(26)
325
(28)
239
(27)
277
(28)
315
(29)
241
(30)
260
(29)
280
(28)
750
Liquid
pressure
(subcool)
294
(17)
335
(17)
376
(17)
267
(15)
314
(19)
360
(22)
267
(21)
309
(22)
351
(23)
252
(22)
294
(23)
337
(23)
236
(24)
273
(24)
309
(27)
227
(26)
264
(27)
301
(30)
230
(35)
251
(32)
273
(30)
-
Suction
pressure
137 138 139 112 111 113 99 99 100 82 84 86 63 62 65 54 55 56 43 43 44
Table 26: 1.5 ton heating charging chart for XA(F,H)*30C and JH(E,V)T*24C in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
475
Liquid
pressure
(subcool)
315
(10)
354
(10)
392
(11)
287
(13)
328
(14)
370
(16)
275
(14)
315
(16)
355
(18)
258
(20)
296
(19)
335
(19)
244
(20)
277
(21)
312
(22)
231
(22)
267
(23)
302
(23)
231
(23)
247
(24)
263
(25)
600
Liquid
pressure
(subcool)
286
(10)
323
(10)
359
(10)
260
(10)
301
(13)
341
(16)
254
(13)
292
(15)
330
(17)
238
(17)
276
(17)
314
(18)
229
(17)
263
(18)
297
(19)
218
(19)
253
(20)
288
(21)
220
(24)
237
(24)
255
(23)
755
Liquid
pressure
(subcool)
267 (9) 304 (9) 342 (9) 242 (7)
286
(11)
327
(16)
242
(13)
281
(15)
319
(17)
230
(15)
267
(16)
306
(17)
220
(16)
254
(18)
288
(19)
211
(18)
245
(19)
280
(21)
207
(25)
226
(23)
245
(20)
-
Suction
pressure
132 133 134 107 107 108 95 95 96 78 80 82 60 61.00 62 51 52 53 41 41 42
R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series 21
Johnson Controls Ducted Systems