Table 20: 5 ton cooling charging chart for XA(F,H)*60H
and JH(E,V)T*60H in downflow, horizontal right, or
horizontal left
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure(psig) and subcooling
(°F) at liquid base valve
55 209 (12) 215 (13) 218 (14) 221 (15)
60 229 (11) 234 (13) 237 (14) 241 (15)
65 248 (11) 253 (13) 256 (13) 260 (14)
70 268 (11) 272 (12) 275 (12) 280 (14)
75 287 (11) 291 (12) 294 (12) 299 (13)
80 312 (11) 315 (12) 318 (12) 323 (13)
85 336 (11) 339 (12) 342 (12) 346 (13)
90 361 (11) 363 (12) 366 (12) 371 (13)
95 386 (12) 387 (12) 390 (12) 395 (13)
100 417 (12) 418 (12) 421 (12) 426 (13)
105 448 (12) 449 (13) 452 (13) 457 (13)
110 479 (12) 480 (13) 483 (13) 488 (13)
115 509 (13) 511 (13) 515 (13) 519 (13)
120 541 (13) 542 (13) 546 (13) 550 (13)
125 572 (13) 573 (13) 577 (13) 581 (13)
Table 21: 5 ton cooling charging chart for XAF*60J and
JH(E,V)T*60J in upflow
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure(psig) and subcooling
(°F) at liquid base valve
55 208 (9) 211 (10) 215 (11) 218 (12)
60 226 (9) 229 (10) 233 (11) 237 (12)
65 245 (9) 248 (10) 252 (11) 256 (11)
70 264 (9) 266 (10) 270 (11) 275 (11)
75 283 (9) 285 (10) 289 (10) 294 (11)
80 307 (9) 309 (10) 312 (10) 318 (11)
85 332 (9) 333 (10) 336 (10) 342 (11)
90 356 (10) 357 (11) 360 (10) 366 (11)
95 381 (10) 381 (11) 384 (10) 390 (11)
100 412 (10) 412 (11) 415 (11) 421 (11)
105 443 (10) 443 (11) 447 (11) 453 (11)
110 474 (11) 474 (11) 478 (11) 484 (12)
115 506 (11) 505 (11) 510 (11) 515 (12)
120 537 (12) 536 (12) 541 (12) 546 (12)
125 568 (12) 567 (12) 573 (12) 578 (12)
Table 22: 5 ton cooling charging chart for XAH*60J and
JH(E,V)T*60J in horizontal left
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure(psig) and subcooling
(°F) at liquid base valve
55 213 (12) 216 (13) 220 (15) 223 (16)
60 232 (12) 235 (13) 239 (15) 242 (15)
65 251 (12) 254 (13) 258 (15) 262 (15)
70 270 (12) 273 (13) 277 (14) 281 (15)
75 289 (12) 292 (13) 296 (13) 301 (15)
80 315 (12) 316 (13) 320 (13) 325 (15)
85 340 (12) 341 (13) 344 (13) 350 (15)
90 365 (13) 365 (14) 368 (13) 374 (15)
95 390 (13) 390 (15) 392 (13) 399 (15)
100 421 (13) 421 (15) 425 (14) 431 (15)
105 453 (13) 453 (15) 457 (15) 463 (15)
110 485 (14) 485 (15) 489 (15) 495 (15)
115 518 (15) 517 (15) 522 (15) 527 (16)
120 549 (15) 548 (15) 554 (15) 559 (16)
125 581 (16) 580 (16) 586 (16) 591 (16)
Table 23: 5 ton cooling charging chart for XA(F,H)*60J
and JH(E,V)T*60J in downflow and horizontal right
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure(psig) and subcooling
(°F) at liquid base valve
55 202 (5) 205 (6) 209 (6) 212 (7)
60 220 (5) 223 (6) 227 (6) 230 (7)
65 238 (5) 241 (6) 245 (6) 249 (6)
70 257 (5) 259 (6) 263 (6) 267 (6)
75 275 (5) 277 (6) 281 (6) 286 (6)
80 299 (5) 300 (6) 304 (6) 309 (6)
85 323 (5) 324 (6) 326 (6) 332 (6)
90 346 (5) 347 (6) 350 (6) 356 (6)
95 370 (6) 370 (6) 373 (6) 379 (6)
100 400 (6) 400 (6) 404 (6) 410 (6)
105 430 (6) 430 (6) 434 (6) 440 (6)
110 461 (6) 461 (6) 465 (6) 470 (7)
115 492 (6) 491 (6) 496 (6) 500 (7)
120 522 (7) 521 (7) 526 (7) 531 (7)
125 552 (7) 551 (7) 557 (7) 562 (7)
R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series20