Table 36: 3.5 ton heating charging chart for XA(F,H)*60G and JH(E,V)T*48G in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
1150
Liquid
pressure
(subcool)
341
(22)
386
(21)
430
(21)
315
(21)
359
(21)
403
(21)
301
(20)
343
(20)
385
(20)
288
(20)
329
(21)
371
(22)
262
(22)
301
(22)
339
(23)
243
(19)
283
(20)
322
(21)
225
(19)
272
(23)
318
(27)
1400
Liquid
pressure
(subcool)
319
(22)
363
(21)
406
(21)
297
(20)
334
(20)
382
(20)
285
(19)
326
(19)
367
(19)
270
(18)
311
(19)
353
(20)
251
(21)
279
(17)
329
(22)
236
(18)
273
(19)
310
(19)
222
(19)
265
(22)
307
(25)
1650
Liquid
pressure
(subcool)
297
(21)
340
(21)
381
(20)
278
(19)
319
(19)
360
(19)
269
(18)
309
(18)
349
(18)
251
(16)
293
(17)
334
(18)
240
(20)
279
(20)
318
(21)
228
(17)
263
(17)
297
(17)
219
(19)
257
(21)
295
(23)
-
Suction
pressure
115 118 121 98 98 100 86 88 90 73 73 73 57 57 58 49 49 50 39 39 40
Table 37: 3.5 ton heating charging chart for XA(F,H)*60G and JH(E,V)T*48G in downflow and horizontal right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
1150
Liquid
pressure
(subcool)
377
(35)
426
(33)
475
(33)
348
(33)
397
(33)
445
(33)
333
(32)
379
(32)
425
(32)
318
(32)
363
(33)
410
(35)
285
(31)
328
(31)
369
(32)
265
(27)
308
(28)
351
(30)
245
(27)
296
(32)
346
(38)
1400
Liquid
pressure
(subcool)
355
(35)
404
(33)
452
(33)
330
(31)
371
(31)
425
(31)
317
(30)
363
(30)
408
(30)
300
(28)
346
(30)
393
(31)
279
(35)
310
(28)
366
(36)
262
(30)
304
(31)
345
(31)
247
(31)
295
(36)
341
(41)
1650
Liquid
pressure
(subcool)
328
(32)
375
(32)
421
(31)
307
(29)
352
(29)
397
(29)
297
(28)
341
(28)
385
(28)
277
(25)
323
(26)
369
(28)
258
(26)
300
(26)
342
(28)
245
(22)
283
(22)
319
(22)
235
(25)
276
(28)
317
(30)
-
Suction
pressure
117 120 123 100 100 102 88 90 92 74 74 74 57 57 58 49 49 50 39 39 40
Table 38: 4 ton heating charging chart for XA(F,H)*60G and JH(E,V)T*48G in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
1350
Liquid
pressure
(subcool)
333
(16)
375
(17)
417
(17)
310
(20)
353
(21)
396
(22)
298
(22)
341
(24)
385
(26)
282
(26)
325
(28)
369
(30)
263
(28)
304
(29)
344
(31)
256
(29)
296
(31)
335
(34)
240
(32)
279
(34)
319
(37)
1600
Liquid
pressure
(subcool)
314
(16)
355
(17)
397
(17)
294
(19)
334
(22)
378
(22)
281
(21)
325
(23)
369
(25)
271
(24)
312
(27)
353
(29)
255
(28)
291
(28)
334
(32)
248
(29)
288
(31)
327
(34)
234
(31)
272
(33)
312
(36)
1850
Liquid
pressure
(subcool)
294
(15)
335
(16)
376
(16)
278
(18)
322
(19)
360
(21)
264
(20)
308
(22)
353
(24)
259
(22)
298
(25)
337
(28)
247
(27)
285
(29)
324
(32)
240
(28)
280
(31)
319
(33)
227
(30)
265
(32)
304
(35)
-
Suction
pressure
120 122 124 96 97 99 84 86 89 72 71 71 55 56 55 48 48 49 36 37 38
R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series 25
Johnson Controls Ducted Systems