Fig. 27: Clean the outside of the device
with a damp cloth.
7.2.3 External cleaning of the device
Do not use liquid cleaners,
sprays, soap or other products
directly on the device.
The ionizing tube is the component of the device that has deteriorated over time to the point where
it needs to be replaced. Components must be replaced when signs of wear appear, indicated
by oxide on the internal mesh of the condenser, which will make it turn white, and by the glass
looking dull. The JONIX cube signals the need for replacement of the ionising tubes, through
the indicator light shown on the display (yellow led), every 8740 hours of operation.
However, when operating in highly contaminated environments, the electronics of the device
could intervene even if this time has not yet elapsed.
7.2.4 Replacement ionizing tubes
Pay particular attention to the
air passage grid: check that
they are not dirty to ensure air
passage.
Replace the ionising generators whenever the corresponding LED starts blinking.
Flashing LED: replacement required