Chapter 5 About Float-free Capsule
95
If the self-test detects a fault in the EPIRB module, the test indicator LED will start flashing at
the end of the test. For fault codes see the table in the Table 5-2.
Note that the extended self-test can only be performed 60 times. After that the self-test will
indicate “maximum number of extended self-tests exceeded”.
Test sequence
Position indicator
RLS indicator
Tes t indicator
Strobe light
EXTENDED
SELF-TEST started
On
Waiting for position
●●● ●●● ●●●
Triple flashes
Position achieved
On for 1 second
Self-test started
On
Signals
Tramsmitted
●●●●
Multiple short
Off periods
RLS enabled*1
On for 1
second
EXTENDED
SELF-TEST
successful
One flash
If one of the above tests are unsuccessful, the remaining test sequences will not be performed, and the test indicator will
indicate self-test failure.
Self-test
failure
Multipule
flashes*2
*1For EPIRBs with RLS (Return Link System) disabled the RLS indicator will remain off.
*2See the Table 5-2 for on failure indications.