Chapter 4 Operation Method
52
2. Check the recording period of the FPC, the FFC, and the internal storage.
Table 4-21 Indication in MEDIUM screen
Indication Color Description
Green
The Data for the specified length of time or more has been
recorded.
Yellow Data for the specified length of time is not recorded.
Gray
The recording period is not measured. After the RCU start,
there is the state of non-measurement for 10 minutes.
[Information]
Because the judgment of each medium is conducted automatically, it is not necessary for a user
to judge it.
3. Judge from the result of Step 2.
If the judgment results have no problem, tap the [Good] button. If the judgment results have a
problem, tap the [Fail] button. Tapping the [Good] button or the [Fail] button, returns to the DATA
CHECK screen.
4.6.6 Saving the judgment results
If the judgment is conducted, the [Save] button in the DATA CHECK screen is enabled.
Tap the [Save] button in the DATA CHECK screen. Then the judgment results of the sensor data,
the audio data, and the medium are saved. The judgement results are saved to the FPC, the FFC,
and the internal storage.
Tap the [Clear] button in the DATA CHECK screen. Then the judgment results that are not saved
yet are all cleared.
[NOTE]
The [Status] indicator becomes yellow just after the equipment started. Because the recorded
time doesn't reach at time necessary for a judgment. If the FPC, the FFC, and the internal
storage is replaced, the [Status] indicator becomes yellow.
Figure 4-38 DATA CHECK screen
[Save] button
[Clear] button