Chapter 8 Specifications
123
8.3 NDV-1950 Recording Control Unit
Performance
a) Interface to the fixed protective capsule unit
1) Standard IEEE802.3 (10Base-T/100Base-TX)
2) Protocol TCP/IP
3) Power supply Supply from the RCU
b) Interface to the float-free capsule unit
1) Standard IEEE802.3 (10Base-T/100Base-TX)
2) Protocol TCP/IP
3) Power supply Supply from the RCU
Power over Ethernet (IEEE802.3af)
c) Sensor data input
1) Standard IEC61162-1/-2/-450
2) Input channel Up to 48 channels
IEC61162-2: up to 2 channels
IEC61162-1: up to 22 channels
IEC61162-450: up to 24 channels (sensor sources
on the network)
3) Recording interval Depends on the input from the sensors (usually 1
second)
d) Bridge audio input
1) Interface Audio signal (microphone unit output)
2) Input channel Up to 12 channels
6 tracks, 1 track is synthesized from 2 channels
3) Recording interval Continuous (1 audio file per minute)
4) Frequency response 150Hz to 6kHz
e) VHF communications audio input
1) Interface 0 dBm, 600-ohm balance
2) Input channel Up to 4 channels
2 tracks, 1 track is synthesized from 2 channels
3) Recording interval Continuous (1 audio file per minute)
4) Frequency response 150Hz to 3.5kHz