Chapter 6 Maintenance and Inspection 
 
105 
6.3 Troubleshooting 
If the S-VDR malfunctions, troubleshoot it according to the following list. Read the cause and take 
the actions recommended on the list. 
If the malfunction persists or there is a problem not listed below, contact your sales representative, 
our sales department, nearest branch office or sales office. 
 
6.3.1 In case of trouble 
 
Trouble symptom  Cause  Actions to take 
The MCB's LED (SYS. or 
REC.) does not turn on. 
The RCU's POWER switch 
does not turn on. 
Turn on the RCU's POWER 
switch. 
The AC-line fuse is blowing 
out. 
After the power supply to the 
RCU is stopped, check the 
PSU's AC-line fuse. If the 
AC-line fuse is blowing out, 
replace with the spare fuse. 
The power supply is not 
supplied from the switchboard. 
Check the switchboard. 
The PSU is breaking down.  Contact your sales 
representative, our sales 
department, nearest branch 
office or sales office. 
The OPU's screen is not 
displayed. 
The OPU's screen brightness 
is becoming low. 
Adjust the screen brightness 
by the rotary knob. 
The life of OPU's LCD is 
approaching. 
Check the OPU's operating 
time. See “4.7.4 Checking the 
replacement parts”. 
If the OPU's operating time is 
over 50,000 hours, it is 
necessary to replace the OPU. 
Contact your sales 
representative, our sales 
department, nearest branch 
office or sales office. 
The power supply is not 
supplied to the OPU. 
1) Check the LAN cable 
2) Reboot the RCU. 
The OPU cannot operate.  The function of rotary knob is 
becoming the operation mode. 
Push the HOME button in the 
OPU. 
The rotary knob is breaking 
out. 
It is necessary to replace the 
OPU. Contact your sales 
representative, our sales 
department, nearest branch 