EasyManua.ls Logo

JRC JCY-1950 - Page 132

JRC JCY-1950
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 About Float-free Capsule
98
3. The test results judge by the LED that is the top of storage module. If the LED blinks only once,
the test is pass.
Table 5-3 Error message by LED blinking
Number of flashing Fault indication
1 None
2 Low power on 406MHz transmitter
3 Low battery voltage
4 Low power on 121.5MHz transmitter
5 PLL on 406MHz transmitter out of lock
6 PLL on 121.5MHz transmitter out of lock
7 EPIRB module not programmed or programming not complete
4. If the test is pass, release the switch and fit the front cover.