Chapter 6 Maintenance and Inspection
107
Code Title Description Actions to take
003 Low battery Cannot operate during
blackout.
Check the RCU's built-in battery.
Turn on the POWER switch and
charge the battery.
004
005
Fan* fail
*: 1, 2
Fan* doesn't work. Need
replacing.
*: 1, 2
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
009 Battery fail Cannot operate during
blackout.
It is necessary to replace the battery.
Please contact our head office, or a
nearby branch or local office to
request servicing.
031 Lost time source VDR time
synchronization doesn't
work.
Check the GPS. If the GPS is working
normally, please contact our head
office, or a nearby branch or local
office to request servicing.
041
042
OPU* fail
*: 1, 2
OPU* doesn't work.
Reboot VDR.
*: 1, 2
1) Check the cable.
2) Reboot the RCU.
101 FPC short period Recording period is
shorter than 48 hours.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few days.
103 FPC record fail Unable to record. Check
unit and cable.
1) Check the cable.
2) Reboot the RCU.
104 FFC short period Recording period is
shorter than 48 hours.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few days.
106 FFC record fail Unable to record. Check
unit and cable.
1) Check the cable.
2) Reboot the RCU.
107 SSD short period Recording period is
shorter than 720 hours.
The image size may be too large
temporarily by radar echo. Check the
gain of the radar and watch the state
for a few weeks.
110
111
SSD* record fail
*:1, 2
Unable to record. Reboot
VDR.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.