Chapter 8 Specifications
125
Performance (continued)
k) External alarm lamp output
1) Interface Dry contact
2) Operation System down (Normal Close / Normal Open)
3) Current 1A or less at DC +24V
0.5A or less at AC 125V
l) GPS select signal input
1) Interface Dry contact (also serve for external contact input)
2) Operation Recording GPS selection (Active Open / Active
Close)
m) Compass safety distance
1) Standard 0.9m
2)
Steering 0.5m
Environmental condition
a) Operating temperature -15°C to +55°C (IEC60945 protected type)
b) Temperature and humidity +40°C, 93% (without dew condensation)
c) Vibration 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Protection class IP22
General specification
a) Power voltage AC 100 to 120V ±10%, 1-phase 50/60Hz (IEC60945)
AC 200 to 240V ±10%, 1-phase 50/60Hz (IEC60945)
b) Power consumption
(Including the fixed protective
capsule unit, and the float-free
capsule unit, the operation panel
unit, and microphone)
230W (In UPS battery charge)
70W (In normal operation)
c) Size 419.5(w) x 214.0(d) x 480.5(h) mm
d) Mass 22.5kg
e) Color N7 semi-gloss texture