4
4.17 ADJUSTMENT OF PERFORMANCE
MONITOR (MON)
[I] Reception Monitor Adjustment (MON Adjustment)
Adjust the circuit for monitoring th
e reception performance of the radar equipment.
Note:
The radar system is equipped with an interswitch.
For adjusting the performance unit, set the interswitch connection to straight, i.e. No.1 scanner is
connected to No.1 display unit as the Master.
Procedures 1. Open the Serviceman Menu.
2. Perform the following menu open procedure to open the Performance
Monitor Adjustment menu.
1. Adjust Menu
4. TXRX Adjustment
4. MON Adjustment
3. Increase or decrease the adjustment value so that the farthest point of
the performance monitor pattern touches the 18.0 nm line.
Note:
During performance monitor adjustment, all acquisitions by the target tracking function are released.
The released target acquisitions are not recovered.
4-18