– 52 –
No.
Description of error
detected
Cause of occurrence expected Items to be checked
E811 Supply voltage fault • When voltage higher than guaranteed
one is inputted.
• The machine has been connected to the
power source supply voltage of which is
200 V or less.
• The machine has been connected to the
power source supply voltage of which is
270 V or more.
• Check whether the supply voltage which
falls outside the "rated voltage ± 10 %" is
applied.
• The inner circuit may have broken.
E922 Main shaft uncontrol-
lable
• In the case the main shaft cannot be
controlled.
E924 Motor driver failure • Motor driver has broken.
E930 Faulty encoder • In the case a motor signal cannot be
input correctly.
• Check the motor signal connector (CN30)
for looseness and slip-off.
• Check whether the motor signal cord is
caught in the machine head or has a break.
E931 Motor hole sensor
failure
E942 Faulty EEPROM • Data cannot be written on the EEPROM.