47 –
E055(*) Production management
error
This error number is displayed in the event
of production management work manage-
ment data fault.
Check whether the data has any fault.
E056(*) Work management error This error number is displayed in the event
of data fault.
Check whether the data has any fault.
E057(*) Pitch time monitor error This error number is displayed in the event
of pitch time monitor data fault.
Check whether the data has any fault.
E065(*) Network transmission failed This message is displayed in the case data
cannot be sent to the personal computer
by way of the network.
Check whether the network has any fault.
E067(*) ID reading failed This message is displayed in the case data
in the ID le is broken.
Check whether the data has any fault.
E070 Slip of belt When the machine head is locked.
Belt is loose.
Check whether there is any holdup when
turning the motor by hand.
Check the belt tension.
E071 Disconnection of motor out-
put connector
Disconnection of motor connector. Check the motor output connector for loose
connection and disconnection.
E072 Overload of motor at the time
of thread trimming motion
Same as E007. Same as E007.
E204(*) USB insertion This message is displayed in the case the
sewing machine is activated with the USB
thumb drive inserted.
Remove the USB thumb drive.
E205(*) Warning of ISS buffer re-
maining amount
This message is displayed in the case the
buffer storage for storing the ISS data is
almost full.
If the sewing machine is continuously used
with the buffer storage full, the stored piec-
es of data will be erased from the earliest
one.
Output the data.
E220 Grease-up warning When the predetermined number of stitch-
es has been reached.
Replenish the specied places with grease
and reset.
(For the details, refer to the data of the ma-
chine head.)
E221 Grease-up error
When the predetermined number of stitch-
es has been reached and the sewing is not
possible.
Replenish the specied places with grease
and reset.
(For the details, refer to the data of the ma-
chine head.)
E302 Fall detection switch failure
(When the safety switch
works)
(Thread trimming knife sen-
sor)
When fall detection switch is input in the
state that the power is turned ON.
Machine-head tilt detector's connecter has
come off.
Thread trimming knife position is not cor-
rect.
Check whether the machine head is tilted
without turning OFF the power switch (sewing
machine operation is prohibited for safety
sake).
Check whether the fall detection switch cord
is caught in the sewing machine or the like.
Check whether the fall detection switch lever
is caught in something.
Check whether the contact of the tilt detection
switch lever with the machine table is inade-
quate. (The table has a dent or the mounting
location of the bed strut is too far)
Check the machine-head tilt detector's con-
nector (CN48) for looseness and slip-off.
Positioning of the thread trimming sensor
Set the function setting No. 74 to 0 (zero)
when the thread trimmer is not installed on
the sewing machine.
E303 Semicircular plate sensor
error
Semicircular plate sensor signal cannot be
detected.
Check whether the machine head corre-
sponds with the machine type setting.
Check whether the motor encoder connector
is disconnected.
E499 Simplied program data fault
Command parameter data is out of speci-
ed range.
Re-enter the relevant simplied program.
Set the simplied program in disable.
E703(*) Operation panel is connect-
ed to the unexpected sewing
machine. (Error of sewing
machine model)
The operation panel and the sewing
machine model do not match in the initial
communication.
Connect the operation panel to the correct
model of the sewing machine.
No.
Description of error detected
Cause of occurrence expected Items to be checked