EasyManua.ls Logo

JUKI SC-920 - Page 50

JUKI SC-920
50 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 48 –
E704(*) System version mismatch The system version is different from the
correct one in the initial communication.
Re-write the system version to the one that
can be used with the operation panel.
E730 Encoder failure
When the motor signal is not properly
inputted.
Check the motor signal connector (CN30) for
loose connection and disconnection.
Check whether the motor signal cord has bro-
ken since the cord is caught in the machine
head.
Check whether the inserting direction of the
motor encoder connector is wrong.
E731 Motor hole sensor failure
E733 Inverse rotation of motor
This error occurs when the motor is run-
ning at 500 sti/min or more in the opposite
direction of that of rotation indication during
motor is running.
Check whether the machine head corre-
sponds with the machine type setting.
Check whether the main-shaft motor encoder
wire is connected incorrectly.
Check whether the main-shaft motor wire for
power supply is connected incorrectly.
E799 Thread trimming operation
time-out
The thread trimming control operation is
not completed within the predetermined
time (within three seconds).
Check whether the machine head actually
installed is different from the machine head
selection.
Check whether the motor-pulley diameter
does not match its setting (effective diame-
ter).
Check whether the belt has slackened.
E808 Solenoid short circuit Solenoid power does not become normal
voltage.
Check whether the machine head cord is
caught in the pulley cover or the like.
E809 Holding motion failure
Solenoid is not changed over to holding
motion.
Check whether the solenoid is abnormally
heated. (CTL circuit board asm. Circuit is
broken.)
E810 Solenoid current abnormality
Solenoid rare short-circuit. Solenoid resistance.
E811 Abnormal voltage When voltage higher than guaranteed one
is inputted.
200V has been inputted to SC-920 of 100V
specications.
JA : 220V is applied to 120V box.
CE : 400V is applied to 230V box.
Check whether the applied power voltage is
higher than the rated voltage + (plus) 10% or
more.
Check whether 100V/200V changeover con-
nector is improperly set.
In the aforementioned cases, POWER p.c.b
is broken.
When voltage lower than guaranteed one
is inputted.
100V has been inputted to SC-920 of 200V
specications.
JA : 120V is applied to 220V box
Inner circuit is broken by the applied over-
voltage
Check whether the voltage is lower than the
rated voltage - (minus) 10% or less.
Check whether 100V/200V changeover con-
nector is improperly set.
Check whether fuse or regenerative resis-
tance is broken.
E906 Operation panel transmis-
sion failure
Disconnection of operation panel cord.
Operation panel has broken.
Check the operation panel connector (CN38)
for loose connection and disconnection.
Check whether the operation panel cord
has broken since the cord is caught in the
machine head.
E924 Motor driver failure
Motor driver has broken.
E942 Faulty EEPROM Data cannot be written on the EEPROM. Turn the power OFF.
No.
Description of error detected
Cause of occurrence expected Items to be checked
* The error number attached with an asterisk (*) is displayed only in the case a fault occurs when the IP/IT pan-
el is connected to the sewing machine.