4.14 Restoring the truck to service after maintenance and repairs
Procedure
Thoroughly clean the truck, see "Cleaning" on page 194.
Lubricate the truck according to the lubrication schedule, see "Lubrication
Schedule" on page 160.
Clean the starter battery, grease the terminals and connect the starter battery.
WARNING!
Faulty brakes can cause accidents
As soon as the truck has been started, test the brakes several times.
XReport any defects immediately to your supervisor.
XTag out and decommission the faulty industrial truck.
XOnly return the truck to service when you have identified and rectified the fault.
Start up the truck, see "Preparing the Truck for Operation" on page 65.