Table 9: CTP2024 Platform Specifications (continued)
SpecificationCategory
Environmental Requirements
32° to 104° F (0° to 40° C)Ambient operating temperature
5% to 90% (noncondensing)Ambient operating humidity
DC Input
–40 to –72 VDCVoltage
3A @ –48 VDCCurrent
144 WPower
2 independent line feedsRedundancy (input power)
AC Input
100–240 VACPower required
50–60 HzAC line frequency
2.0Nominal current (115V amps)
200 WPower
3 ft. (90 cm) behind device or rack.
Do not block air vents on the front or back of the device.
Space Requirements
Air intake occurs from the front of the device.
Air is exhausted out the back of the device.
Airflow
36