• Back-to-front (cold air enters through the vents on the rear panel of the switch and hot air exhausts
through the vents on the front panel), indicated by the AIR IN label and the Juniper Azure Blue
handle.
Table 49 on page 96 lists the AC power supply models and the direcon of airow in them.
Table 49: Airow Direcon in AC Power Supply Models for EX4400 Switches
Model Direcon of Airow
• JPSU-550-C-AC-AFO
• JPSU-1050-C-AC-AFO
• JPSU-1600-C-AC-AFO
Front-to-back—that is, cold air enters the chassis through the vents on
the front panel of the chassis and hot air exhausts through the vents on
the rear panel of the chassis, indicated by the AIR OUT label and the
Juniper Gold handle.
JPSU-550-C-AC-AFI Back-to-front—that is, cold air enters the chassis through the vents on
the rear panel of the chassis and hot air exhausts through the vents on
the front panel of the chassis, indicated by the AIR IN label and the
Juniper Azure Blue handle.
Specicaons of the Power Cord for AC Power Supplies for EX4400 Switches
Each AC power supply has a single AC appliance inlet that requires a dedicated AC power feed. A
detachable AC power cord is supplied with each AC power supply. We ship the 550-W AC power
supplies with AC power cords with the C13 coupler type and the 1050-W and the 1600-W AC power
supplies with the C15 coupler type as described by Internaonal Electrotechnical Commission (IEC)
standard 60320. The plug end of the power cord ts into the power source outlet that is standard for
your geographical locaon.
NOTE: In North America, AC power cords must not exceed 14.75 (4.5 m) in length, to comply
with Naonal Electrical Code (NEC) Secon 400-8 (NFPA 75, 5-2.2) and Canadian Electrical
Code (CEC) Secon 4-010(3).
Table 50 on page 97 lists the AC power cords specicaons provided for the 550-W power supplies for
each country or region.
96