The front mounng bracket assembly is made up of a side rail to which an L-shaped bracket is
aached.
• Flat head 4x6-mm Phillips screws to aach the front mounng bracket assembly to the chassis—12
(provided with the four-post rack mount kit)
• Rear mounng brackets—2 (provided with the four-post rack mount kit)
• Covers for the empty extension module slot and the empty power supply slot—provided with the
switch
You can also mount an EX4400 switch:
• In a recessed posion inside a 19-in. four-post rack by using the recessed-mounng brackets
provided with a separately orderable four-post rack mount kit.
• On a two-post rack or on two posts of a 19-in. four-post rack by using the two-post mounng
brackets and screws provided with the switch.
• On a desk or other level surface by using the rubber feet provided with the switch.
• On a wall by using a separately orderable wall mount kit.
To know the part numbers for ordering the separately orderable mounng kits, see the EX4400
Switches Datasheet.
NOTE: One person must be available to li the switch while another person secures the switch
to the rack.
CAUTION: If you are mounng mulple units on a rack, mount the heaviest unit at the
boom of the rack, and then mount the other units from the boom of the rack to the
top in decreasing order of the weight of the units.
To mount an EX4400 switch ush with the front posts of a 19-in. four-post rack:
1. Place the switch on a at, stable surface.
2. Wrap and fasten one end of the ESD wrist strap around your bare wrist, and connect the other end
of the strap to a site ESD point.
3. Align the front mounng bracket assembly (provided with the four-post rack mount kit) along the
side panel of the switch such that the front of the bracket assembly is ush with the front panel of
the switch chassis.