Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Software features
Duplex SC/PC connector (Rx and Tx); single-mode fiber
Optical interface supportSee Table 13 on page 41
Cables and connectors
One tricolor per port:
OffNot enabled
GreenOnline with no alarms or failures
AmberOnline with alarms for remote failures
RedActive with a local alarm; router has detected a failure
LEDs
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE),
far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Frame error
Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Yellow alarm bit (X-bit) disagreements
Alarms, errors, and
events
Layer 2 per-queue and per-channel packet and byte countersInstrumentation
(counters)
Table 13: Optical Interface Support for Channelized OC12 IQ PICs
Intermediate Reach (IR)Parameter
Single-modeOptical interface
Channelized OC12 IQ PIC 41
Channelized OC12 IQ PIC