The NetScreen-50 device uses a 2.5 amp slow-blow fuse rated for 250 volts.
To replace a failed fuse on the NetScreen-50 device:
1. Take the device off-line, turn the power switch off, and disconnect the power
cable.
2. Using a screwdriver, separate the lid of the external fuse cover from the surface
of the power outlet.
3. Manually remove the fuse assembly from the device.
4. To replace the fuse assembly, enter the new fuse into the opening and slide it in
until the fuse clicks into place.
5. Replace the power cable and turn the device power switch on. Reconnect
network cables.