1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the ESD point on the chassis. There is an ESD point located next to the protective earthing terminal
and below PSU 5 on the PTX10008 rear panel (see Figure 157 on page 294) and below PSU_9 on the
PTX10016 (see Figure 158 on page 294).
Figure 157: ESD Point on PTX10008 Chassis Rear
1ESD point
Figure 158: ESD Point on PTX10016 Chassis Rear
1ESD point
2. Make sure that the voltage across the DC power source cables leads is 0 V and that there is no chance
that the cables might become active during the removal process.
3. Ensure the black power supply output switch, to the right of the captive screw, is set to the standby
position.
4. Unscrew the captive screw counterclockwise by using the Phillips (+) screwdriver, number 1.
294