1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the ESD point on the chassis. There is an ESD point located next to the protective earthing terminal
and below PSU 5 on the PTX10008 rear panel (see Figure 176 on page 313) and below PSU_9 on the
PTX10016 (see Figure 177 on page 313).
Figure 176: ESD Point on PTX10008 Chassis Rear
g100611
1
1ESD point
Figure 177: ESD Point on PTX10016 Chassis Rear
g100612
1
1ESD point
2. Taking care not to touch power supply components, pins, leads, or solder connections, remove the
power supply from its bag.
3. Peel back and remove the protective plastic wrap that covers all four sides of the power supply.
4. Ensure the power switch is set to the standby (O) position. This switch turns off the output voltage; it
does not interrupt DC.