2DM556
Digital Stepper Drive
Manual
Shenzhen Just Motion Control Electro-mechanics Co., Ltd
TEL:+86-0755-26509689
FAX:+86-0755-26509289
www.jmc-motion.com
Email:info@jmc-motion.com
Address: Floor2, Building A, Hongwei Industrial Zone No.6,
Liuxian 3rd Road, Shenzhen. China
Question and Answer IconNeed help?

Do you have a question about the Just Motion Control 2DM556 and is the answer not in the manual?

Summary

Overview

Features

Ports Introduction

ALM Signal Output Ports

Describes the ALM signal output ports.

Control Signal Input Ports

Details the input ports for control signals.

Power Interface Ports

Explains the power connection ports.

Technological Index

Connections to Control Signal

Connections to Common Anode

Wiring diagram for common anode control signal connection.

Connections to Common Cathode

Wiring diagram for common cathode control signal connection.

Connections to Differential Signal

Wiring diagram for differential signal control connection.

Connections to 232 Serial Communication Interface

Details the serial communication interface connections.

Sequence Chart of Control Signals

Explains the timing sequence for PUL, DIR, and ENA signals.

DIP Switch Setting

Activate Edge Setting

Configures the activation edge for control signals.

Current Setting

Sets the operating current for the drive using DIP switches.

Standstill Current Setting

Configures the current level when the motor is not moving.

Micro Steps Setting

Defines the micro-stepping resolution via DIP switches.

Faults Alarm and LED Flicker Frequency

Faults Alarm and LED Flicker Frequency

Details fault conditions indicated by LED flicker patterns.

Appearance and Installation Dimensions

Typical Connection

Typical Connection Diagram

Illustrates the standard wiring for the 2DM556 drive.

Parameter Setting

Processing Methods to Common Problems and Faults

Power on Power Light Off

Troubleshooting step for when the power light is off.

Power on Red Alarm Light On

Troubleshooting step for when the red alarm light is on.

After Input Pulse Signal but the Motor Not Running

Troubleshooting for motor not running after input pulse.

Just Motion Control 2DM556 Specifications

General IconGeneral
Max Output Current5.6A
Protection FeaturesOver-voltage, Over-current, Short-circuit
Storage Temperature-20°C to 70°C
Communication InterfaceRS485 (Modbus RTU)
Logic Input Current7-16mA (Typical 10mA)