K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 07: Program Priority (Security Level)
Program
variables and
program
priority
protection
table
The following table is a listing of variables that are permitted to be
altered when the stated program priority selection is in place. A control
listing is also provided.
Protection Control Editable Variables
All Run/Stop is
active. Mass/Vol
is active plus any
function key for a
machine.
Any variable that can be edited
on the machine is allowed to be
changed under this protection.
SP
Run/Stop is
active. Mass/Vol
is active only.
Only the Setpoint of the
machine can be changed.
SP and Alarm Run/Stop is
active. Mass/Vol
is active plus
Alarm Ack/Clr is
used.
The following variables can be
changed:
LWF Machines:
Mass Flow Error +
Mass Flow Error -
Drive Command High Limit
Drive Command Low Limit
Alarm Delay
Start-Up Delay
Initial FeedFactor
FeedFactor Alarm Limit
Locked Out None for selected
machine.
No variables for the selected
machine can be changed.