805.9
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
Common Messages and Meanings from K-Cdr
Introduction
This section will present some common messages as displayed by the
K-Commander (K-Cdr) and provide an explanation and resolution to
them. Alarm specific messages are found in the Alarm page 03.
Common
message
listing with
resolution
The following table outlines common K-Cdr messages.
Message Meaning Resolution
Feeder Range Error The entry is outside
the limits of the
variable selected
Re-check the entry.
Check the range
limits of the variable.
Hint: see the Serial
Protocol for those
limits.
NAK Due to Feeder
Running
Some variables like
scale range cannot be
changed while the
feeder is running
Stop the feeder to
make this change.