EasyManuals Logo

KAESER ASK 40 User Manual

KAESER ASK 40
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Fig. 14 Activating and deactivating the MODULATING control
1 Control valve (proportional control)
2 Shut-off valve
Open or close the shut-off valve, depending on the required control mode.
The regulating valve is factory set. Consult with KAESER SERVICE before changing.
7.8 Starting the machine for the first time
Precondition No personnel are working on the machine.
All access doors are closed.
All removable panels in place and secured.
1. Open the user's shut-off valve to the air network.
2. Switch on the power supply disconnecting device.
After the controller has carried out a self-test, the green
Control voltage
LED is lit continuously.
3. If required:
Change the display language as described in chapter 7.10.
4. Press the «ON »key.
The compressor motor runs up and after a short time the machine switches to LOAD and deliv‐
ers compressed air.
Watch for any faults occurring in the first hour of operation.
After the first 50 operating hours, check all electrical connections and tighten where nec‐
essary.
Does the machine stop when the compressor motor rotates in the wrong direction?
Switch off and lock out the power supply disconnecting (isolating) device and check that
no voltage is present.
Changeover phase lines L1 and L2.
Acknowledge any existing alarm messages and switches the machine on again.
7 Initial Start-up
7.8 Starting the machine for the first time
50
Operating Manual Screw Compressor
ASK 901824 12 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASK 40 and is the answer not in the manual?

KAESER ASK 40 Specifications

General IconGeneral
ModelASK 40
CategoryRotary Screw Compressor
Motor Power22 kW
Noise Level68 dB(A)
TypeRotary Screw

Related product manuals