10 Kamstrup A/S • 55122714_A2_GB_04_2021
flowIQ® Gateway
3.7.1.1 Supported flowIQ® meters
flowIQ® meters Proprietary Kamstrup communication
flowIQ® 2200 with wM-Bus/linkIQ® module 61/62
flowIQ® 3200 with wM-Bus/linkIQ® module 63/64
3.7.1.2 Supported data from flowIQ® 2200/3200 meters
Temperature and Advanced Leak Detection data is not forwarded from flowIQ® Gateway.
If you wish to receive this data, import the flowIQ® meter in READy Manager
The following data is synced between flowIQ® Gateway and flowIQ® 2200/3200 meters:
Volume 1
Flow (V1)
Info codes (see the following section)
Please refer to the specific communication module's data sheet on products.kamstrup.com for
further information about data content.
3.7.1.3 Supported info codes from flowIQ® 2200/3200 meters
The connected flowIQ® 2200/3200 meters can forward the following alarms/info codes to
flowIQ® Gateway. The gateway maps the info codes to its own interpretation of the alarms/info codes:
flowIQ® Gateway flowIQ® 2200/3200
The connected meter is Dry V1 Air Dry
The connected meter has Reverse flow V1 Reverse Reverse
The connected meter has registered a Leak Leak out Leak
The connected meter has registered a Burst Burst out Burst
The connected meter has registered Flow above Q
4
V1 is above Q
s
Flow above Q
4
See section 8.2 "Alarms and info codes" for a complete overview of alarms and info codes.
3.7.2 Module slot 1 and 2
Module slots 1 and 2 are for plugging in modules offering different communication types and
protocols.