121
LINKS
The LINKS command displays a list of current AX.25 links existing in the node. Links
displays the callsign of the two connected stations, the AX.25 State (normally 5), the
Port number, the Type of link (U = Uplink, D = Downlink, and X = Crosslink), and the
AX.25 Version in use (1 or 2).
EXAMPLE - Links
K-Net responds: WK5M KARL S=5 P=1 T=U V=2
This shows that WK5M is connected to KARL, the AX.25 state is 5 (connected), using
port 1, it is an uplink using AX.25 version 2. Note: An uplink is an end user/server
connected to the node, a downlink is from the node to an end user/server, and a
crosslink is from the node to another node.
Possible State Values (S) are:
1 Disconnected
2 Connect in progress
3 FRMR condition detected
4 Disconnect attempt in progress
5 Connected
6 Waiting acknowledgment
7 Device busy
8 Remote device busy
9 Both devices busy
10 Waiting acknowledgment and device busy
11 Waiting acknowledgment and remote device busy
12 Waiting acknowledgment and both devices busy
The next six commands deal with the ISO OSI (Open Systems Interconnection)
Reference Model of network structure, in particular level 3 (Network Layer), and level 4