CAN RANGER OPERATION
7
(or zero) the angle sensor,
position the bucket to what
you want level to be. NOTE:
This must be within 5 degrees
of what the sensor thinks is 0.
Then with the transmitter and
receiver on, push E-STOP
down, AUTO TILT, AUX off,
Crane Speed Slow. Then hold
Tilt Up and press the HORN.
The receiver module can
identify problems with the
system in the form of an error
code. Check the red indicator
or display window under the
HISTOGRAM screens to see
the errors. The green LED
indicator will blink on the
receiver during normal
operation.
The display on the receiver
can provide the user with
diagnostic information, and
can be used to set up the
system. The 5 push buttons
on the controller are used to
navigate through the screens.
The five main menus are
DIAGNOSTIC, CALIBRATION,
HISTOGRAM, LCD CONTRAST
and LOCAL OPERATION.
The DIAGNOSTIC menu lets
you see the status of the
inputs and the outputs.
The CALIBRATION Menu lets
you set up the actuators, the
engine RPM, and the other
options.
The HISTOGRAM Menu lets
you check the errors. You can
check on just the active
errors, all the errors, or clear
the error counts.