CAN RANGER OPERATION
8
The LCD CONTRAST Menu
lets you adjust the LCD
Contrast.
The LOCAL OPERATION
Menu lets you use the
Receiver’s buttons to
manually control the
actuators. This option is used
for equipment without manual
override valve handles.
Use the Left and Right arrows
to select the actuator you
want to control. Hold the SET
button to activate the selected
actuator. Use the Up and
Down arrows to extend and
retract the actuator.
OUTPUTS
Each of the outputs from the
receiver module is designed
with built-in short circuit and
overload protection. The
outputs can also detect a no-
load or broken wire condition.
These error conditions are
evident by the red LED
indicator or the alphanumeric
display on the receiver
module or the HISTOGRAM
page on the optional Palm
Pilot™.
The RPM outputs can be used
as either ON/OFF (RPM +/-),
or variable RPM for connection
to ECM. Analog RPMs provided
are: PWM, inverted PWM or
DC voltage output. There are
preset parameters for
different type of engines (i.e.
Cummins engine) under RPM
calibration.
The ON/OFF outputs will
indicate an error under no
load or broken wire status if