EasyManua.ls Logo

KEB COMBIVERT F6 - Technical Data

KEB COMBIVERT F6
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB - 25
Terminals 400 V Class
Housing size 23…27 DC versionSpecial ver-
sion without GTR
Terminal in accordance with table 2.5
++
- -
U
V
W
+ -
T2T1
Name Function No.
++, --
DC voltage input
420…746 V DC (400V class)
1
U, V, W Motor connection
+, -
DC link voltage 420…746 V DC
(400V class)
Connection for braking module,
lterorDClinkcoupling
(unsuitable for DC supply)
4
T1, T2 Connection for temperature sensor
3
Connection for shielding / earthing
5
Housing size 23…27 DC version with GTR7 Terminal in accordance with table 2.5
++
PA
- - U V W
K1K2T1T2
PB
Name Function No.
++, -- DC voltage input
420…746 V DC (400V class)
5
U, V, W Motor connection
PA, PB Connection for braking resistor
1
T1, T2 Connection for temperature sensor
3
K1, K2 GTR7 monitoring (optional)
Connection for shielding / earthing
5