Page #4 background imageLoading...
Page #4 background image
4
Setup functions
Welding current upslope time * A1
ON The upslope time depends on the welding
current
OFF The upslope time is fixed
Welding current downslope time * A2
ON The downslope time depends on the welding
current
OFF The downslope time is fixed
TIG Antifreeze * A3
ON TIG Antirfeeze is ON
OFF TIG Antifreeze is OFF
MMA Antifreeze * A4
ON MMA antifreeze is ON
OFF MMA antifreeze is OFF
VRD * (MMA open circuit voltage) A7
ON VRD-function: MMA open circuit voltage < 35
Vdc
OFF Normal open circuit voltage is 50 Vdc
2T-function´s downslope cutoff A8
ON On 2T-function the downslope is cut off by a
quick press on the start switch
OFF Quick press on the start switch has no function
Tacking automatics A9
ON Tacking automatics is ON; no downslope, if the
weld is shorter than 3 s
OFF Tacking automatics is OFF
Current upslope speed A10
ON If upslope time is 0,0 s, it goes to 0,2 s from the
halfway of currents > 100 A.
OFF Maximum current upslope speed
Method selection by remote
controller *
A12
ON Method selection; TIG: minimum end of the
range of the remote controller, MMA: the
maximum end of the remote controller range
OFF The remote controller works as a normal current
adjustment
Entering the advanced setup press and hold the setup and Return buttons at the same
time. Changing the level press Setup button shortly
* Setting is always on ** Adjustable also by the Quick Setup

Other manuals for Kemppi MLS 2300 ACDC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi MLS 2300 ACDC and is the answer not in the manual?

Kemppi MLS 2300 ACDC Specifications

General IconGeneral
BrandKemppi
ModelMLS 2300 ACDC
CategoryWelding System
LanguageEnglish

Related product manuals