4
Setup functions
Welding current upslope time * A1
ON The upslope time depends on the welding
current
OFF The upslope time is fixed
Welding current downslope time * A2
ON The downslope time depends on the welding
current
OFF The downslope time is fixed
TIG Antifreeze * A3
ON TIG Antirfeeze is ON
OFF TIG Antifreeze is OFF
MMA Antifreeze * A4
ON MMA antifreeze is ON
OFF MMA antifreeze is OFF
VRD * (MMA open circuit voltage) A7
ON VRD-function: MMA open circuit voltage < 35
Vdc
OFF Normal open circuit voltage is 50 Vdc
2T-function´s downslope cutoff A8
ON On 2T-function the downslope is cut off by a
quick press on the start switch
OFF Quick press on the start switch has no function
Tacking automatics A9
ON Tacking automatics is ON; no downslope, if the
weld is shorter than 3 s
OFF Tacking automatics is OFF
Current upslope speed A10
ON If upslope time is 0,0 s, it goes to 0,2 s from the
halfway of currents > 100 A.
OFF Maximum current upslope speed
Method selection by remote
controller *
A12
ON Method selection; TIG: minimum end of the
range of the remote controller, MMA: the
maximum end of the remote controller range
OFF The remote controller works as a normal current
adjustment
Entering the advanced setup press and hold the setup and Return buttons at the same
time. Changing the level press Setup button shortly
* Setting is always on ** Adjustable also by the Quick Setup