ES749 Flow Computer
104
10. Flow Computer Setup Software
The ES749 setup program provides for conguring, monitoring and controlling a ES749 unit.
Sample applications are stored in disk les. The setup program calls these Templates. You
can store the setup from the program’s memory to either the ES749 (Downloading the le)
or to a disk le (Saving the le) for later usage. Similarly you can load the setup in program
memory from either a disk le (Opening a le) or from the ES749 unit (Uploading a le).
The program can monitor outputs from the unit while it is running.
The program can reset alarms and totalizers.
The peak demand may be reset when the option is supplied.
For assistance there are mini-helps at the bottom of each screen in the program. There is
also context sensitive help available for each screen accessible by pressing the F1 key.
10.1 System Requirements:
IBM PC or compatible with 386 or higher class microprocessor
4 MB RAM
3 MB free disk space
VGA or higher color monitor at 640 x 480
Microsoft
®
Windows™ 3.1 or 3.11 or Windows 95/98™ or higher
Communication Port - RS-232
RS-232 Cable (customer supplied)
10.2 Cable and Wiring Requirements:
The serial communication port on your PC is either a 25 pin or 9 pin connector. No cabling
is supplied with the setup software. A cable must be purchased separately or made by
the user. It is recommended to purchase a serial cable which matches the available
communication port on you PC and a 9 pin male connection for the ES749 serial port.
10.3 Installation for Windows™ 3.1 or 3.11
The Setup Software includes an installation program which copies the software to your hard
drive.
Insert Setup Disk 1 in a oppy drive.
In the Program Manager, click File, and then select Run.
NOTE: For Windows 95™ Click the Start button, select Run and proceed as
follows:
Type the oppy drive letter followed by a colon (:) and a backslash (\), and the word setup.
For Example:
a:\setup
Follow the instructions on your screen.
10.4 Using the Flow Computer Setup Software
The setup software window consists of several menu “Tabs”. Each tab is organized into
groups containing various conguration and/or monitoring functions. To view the tab
windows, simply click on the tab. The previous tab window will be hidden as the new tab
window is brought to the foreground.
Caution: It is required that the ES749 unit which is being congured be kept in the
operating mode while using the setup diskette. If not, uncertainty exists as to
what information will be retained when the session is concluded.
10.5 File Tab
The File Tab has three sections. Any of the options on this tab can also be accessed from