ES749 Flow Computer
80
PRINT INITIATE
DATALOG ONLY
PRINT INTERVAL
PRINT TIME
DATALOG FORMAT
COMMUNICATION
6.13
COMMUNICATION
(Continued)
Datalogger and/or printing variables and parameters over the serial
RS-232 interface can be initiated at regular intervals (INTERVAL) or
daily at a xed time (TIME OF DAY) or by front key depression.
Note:
Printing can always be initiated by pressing the PRINT key.
Selection:
NONE, TIME OF DAY, INTERVAL, ENABLE PRINT KEY
Display: TIME OF DAY
PRINT INITIATE
Select YES or NO for Datalog Only prompt.
Selection:
YES - Data is logged but no information is sent on print event.
NO - Data is logged and immediately transmitted.
Display: YES
DATALOG ONLY
Dene a time interval. Variables and parameters will be periodically
logged at regular intervals of this value of time. The setting "00:00"
deactivates this feature.
Input:
Time value in hours & minutes (HH:MM).
Display: 00:00
PRINT INTERVAL
Dene the time of day that variables and parameters will be logged
out daily.
Input:
Time of day in hours & minutes (HH:MM).
Display: 00:00
PRINT TIME
Dene the Datalog Format.
Selection:
DATABASE - Data sets sent in comma seperated variable
format.
PRINTER - Individual output variables sent with text
label and units suitable for printing.
Display: PRINTER
DATALOG FORMAT

Table of Contents